Wellness zonesProductsGalleryPricingProjectsInsightsBuild your setContactBahasa Indonesia
Home/Insights/Size the sauna right, or it never gets hot

Planning

Size the sauna right, or it never gets hot

Half the 'broken' saunas we are called to fix were never broken - they were undersized heaters in oversized rooms, planned off a furniture catalogue. The sizing method we use on every build, from villa two-seater to resort ten.

Planning guide · 2026-08-25

Large commercial sauna interior with two tiers of mahogany benches

Sizing runs in one direction: people → benches → cabin → volume → heater → electrical. Skip a step and the error lands in the last one - usually as a 6 kW heater gasping at a glass-walled 14 m³ room at 7 pm in the rain.

Step 1: people, honestly counted

Count the peak hour, not the brochure: a villa couple is 2; a padel club's post-match wave is 4-6 at once; a hotel spa cycling guided groups wants 8-10. Each seated adult needs ~60 cm of bench; lounging doubles it. Our standard tiers - and their cabins - follow:

PeopleCabinVolumeHeaterVenue
21.6 × 1.6 m~5.4 m³6 kWvilla, studio
42.0 × 2.0 m~8.4 m³9 kWlarge villa, small gym
62.4 × 2.2 m~11 m³10.8 kWclub
83.0 × 2.4 m~15 m³13.5 kWhotel spa
103.6 × 2.6 m~21 m³15 kWresort

Step 2: the 1 kW per m³ rule - and its tropical asterisks

Base rule: ~1 kW of heater per cubic metre of cabin. Then the asterisks that matter here: every square metre of glass behaves like extra volume (add ~1.2 m³ worth per m² of glazing); an uninsulated stone or concrete wall steals heat all evening; and commercial duty wants the next heater up, not the exact match - stone mass is what recovers temperature between guest waves. This is why our cabins pair fixed size-to-heater combinations: the guesswork is pre-made.

Step 3: geometry guests feel

  • Ceiling at 2.1-2.2 m: higher wastes heat above heads; lower cramps steam room ergonomics.
  • Two bench tiers from 6 people up: heat stratifies, and tiers sell the choice (novices low, veterans high).
  • Door swings out, hinge away from the heater - safety code and common sense in one.
  • Heater guard rail and lockable wall controller for commercial rooms - staff set 85-95 °C; guests get heat, not switches.
  • Ventilation: intake under the heater, exhaust behind the top bench - the tropical anti-mould detail most builds miss.

Electrical, before the electrician asks

6 kW runs on robust single-phase; from 9 kW plan 3-phase. A 15 kW resort heater is a 3×32 A conversation your building engineer wants early - which is why every free layout ships with the electrical reservation sheet. Pair the cabin with cold and the numbers combine: the configurator matches heater and chiller in one pass.

Can I go bigger than 10 people?

Yes - beyond ~21 m³ we design custom with multiple heaters or a commercial stove. That is a drawings conversation, not a configurator one.

Glass front on a small sauna - bad idea?

No, just an honest one: glass adds heater demand. A 2-person cabin with a glass front sizes like a 3-person - we pre-adjust, you enjoy the view.

How long from cold to ready?

40 minutes to working temperature on our builds - then the stone mass holds through guest churn. If a sauna needs 90 minutes, it was sized wrong.

Does the sauna need to match the ice bath capacity?

Roughly: guests alternate, so a 6-person sauna pairs well with 2 tubs or one double. The sets page shows balanced circuits.

Keep reading

Guides that pair well with this one

Questions?

Ask us directly - we answer with numbers

Get a free layout & quote

Tell us about the property - we reply with a layout sketch, equipment list and an indicative budget.

WhatsAppPricing